2015 Venus Concepts Versa with 8 Handpieces (km/nel)x - Rock Bottom Lasers

Shop by Category

Sale!

2015 Venus Concepts Versa with 8 Handpieces (km/nel)x

Product Question
Email Product

2015 Venus Concepts Versa with 8 Handpieces – Large Spot Size 690nm IPL Hair Removal, Small Spot Size 690 IPL Hair Removal, 580 IPL Pigmented Lesions, 515 IPL Vascular Lesions, 420 IPL Acne AC Dual IPL, Viva RF Resurfacing, Diamond-Polar Face Tightening, and Octi-Polar Body Tightening; Manufactured 06/2015; Excellent Cosmetic and Operating Condition, Single Owner; Software Version: GUI 2.0.0.395; Reason for Selling: Closing Business; Included Handpieces and Usage: HR690XL = 231 Pulses, HR690 = 16,677 Pulses, SR580 = 231 Pulses, SR515 = 16,677 Pulses, ACDual = 18 Pulses; Viva = 20,107 Pulses, Diamond Polar = 9 Hours 15 Minutes, OctiPolar = 3 Hours 20 Minutes; Includes: (3) Operator Eyewear, (1) Patient Eyewear, Water Refill Kit, Operator Manual, and 90 Day Warranty. (km/nel34x)

Original price was: $135,000.00.Current price is: $33,975.00.

Out of stock

Dimensions: WxDxH(not packed)65x55x110cm (25.6×21.7×43.3in)
System Console Weight: 35kg (77.2 lbs)
Electrical Requirements:100-240 VAC, 16A, 50 – 60 Hz, Single Phase

Maximum RF Output Power:Diamondpolar:75 W
Octipolar:150 W
Diamondpolar:75 W
Octipolar:150 W
RF Output Frequency:1 MHz
Magnetic Pulse Frequency:15 Hz
Magnetic Field:Up to 15 Gauss

SR515 & SR580 IPL
Indicated Uses:515nm = Superficial Vascular and Pigmented Lesions; 580nm = Skin Rejuvenation
Wavelength:515 – 950nm, 580 – 950nm
Optical Energy:5 – 25J cmtwo
Pulse Duration:5 – 20ms
Spot Size:10mmx30mm
Pulse Repetition Rate:Up to 3Hz

HR650 & HR690 IPL
Indicated Uses:650nm & 690nm = Hair Removal
Wavelength:650 – 950nm, 690 – 950nm
Optical Energy:5 – 20Jcmtwo
Pulse Duration:20 – 50ms
Spot Size:10mmx30mm, XL:20mmx30mm
Pulse Repetition Rate:Up to 3Hz

Venus Versa combines three unique, highly effective technologies in one workstation for true versatility. The device can be customized to grow with your practice-start with one set of applicators and add more as you grow to maximize the treatments you can offer at your practice. Venus Versa™ can also be easily moved between treatment rooms, making it the ideal system for locations with limited space.

INTENSE PULSED LIGHT (IPL) WITH SMARTPULSE
Photorejuvenation/photofacial, acne treatment, hair removal
All IPL applicators include innovative SmartPulse technology to ensure precise and consistent energy delivery through advanced pulse optimization

Pulses of broad – spectrum light are selectively filtered and delivered into the skin, where it’s absorbed by target chromophores and transformed into therapeutic heat

For photorejuvenation photofacial, target chromophores are oxyhemoglobin for vascular lesions and melanin for pigmented lesions in the skin

For hair removal, target is melanin in the hair shaft

For dual – light acne treatment, blue light targets the porphyrian produced by Propionibacterium Acnes bacteria, leading to destruction of the bacteria, while the longer wavelength of red light controls inflammation and promotes faster healing

Real – time cooling system monitors the light guide temperature 1,000 times a second for unparalleled patient safety and comfort
NANOFRACTIONAL RADIO FREQUENCY (RF) WITH SMARTSCAN
Skin resurfacing

Designed to resurface the skin, which helps reduce the appearance of acne scars, traumatic scars, striae, rosacea, dyschromia, deep wrinkles, enlarged pores, and uneven skin texture and pigmentation

Tip is the largest spot size in the industry and delivers up to 700 pulses

Energy is distributed through small footprint per pin (150 x 20 microns) at variable energy densities in a single tip, reducing the risk of post -inflammatory hyperpigmentation (PIH) and leaving sufficient intact tissue in between, for faster wound healing, uniform post – treatment tissue appearance, and low downtime

SmartScan uses a unique algorithm and pattern selection technology that enables the operator to generate customized patterns for maximum flexibility and control during the treatment

(MP)2 TECHNOLOGY
Wrinkle reduction
Unique combination of Multi – Polar Radio Frequency (RF) and Pulsed Electro Magnetic Fields (PEMF)

Multi – Polar RF uses a complex algorithm to deliver homogeneous energy and volumetric heating to multiple tissue depths, allowing for quick and safe buildup of heat and easy maintenance of therapeutic temperature throughout the treatment

Effect of Multi – Polar RF is enhanced by PEMF, a non – thermal mechanism emitted through the applicator’s electrodes

Through synergistic (MP)2, RF heats and directly stimulates fibroblasts, while PEMF is known to promote angiogenesis and induce fibroblast proliferation through release of the growth factor FGF – 2, resulting in increased collagen synthesis

(MP)2 is therefore effective in remodeling of collagen, which reduces rhytides and wrinkles, and the creation of new capillaries, which renews blood supply

Date Sold

* Shipping is included in the Continental USA only. Any shipment outside the lower 48 United States will be shipped at an extra cost. If you live outside this area, please contact us for a free shipping estimate.

Join Our Mailing List

Subscribe to our email list to receive updates on our latest equipment listings.