Elos Plus CONSUMABLES & RECERTIFICATION
Sublative Applicator/Handpiece Consumable Required: Standard 64 Suplative iD Tip;
Cost of Tips: 100 Pulse Tip = $50, 200 Pulse Tip = $75, 400 Pulse Tip = $150
Where can the Tips be Purchased? Syneron Candela
Does Syneron Candela Charge a Recertification fee Service and the Purchase of Consumables? Yes
Recertification Fee: $30,000
Elos Plus PRODUCT SPECIFICATIONS
Sublative RF Applicator: Spectrum N/A; Light Fluence N/A; Radio Frequency RF Energy Up to 62 mJ/pin; Treated Area – Standard 64 = 12×12 mm, Focal 44 = 11×3 mm; Pulse Rep Rate 1 Hz; Cooling N/A; Ablation & Skin Resurfacing, Skin Rejuvenation for an Increase in Collagen
Sublime Applicator: Spectrum 700-2000 nm IPL; Light Fluence Up to 6 W/cm²; Radio Frequency RF Energy Up to 120 J/cm³; Treated Area 12×8 mm; Pulse Rep Rate 1 Hz; Cooling 10 degrees C; Facial Contouring and Wrinkle Treatment
SR Applicator: Spectrum 580-980 nm IPL; Light Fluence Up to 45 J/cm²; Radio Frequency RF Energy Up to 25 J/cm³; Treated Area 25 x 12 mm; Pulse Rep Rate 1 Hz; Cooling 5 degrees C; Vascular & Pigmented Lesion Treatment
SRA Applicator: Spectrum 470-980 nm IPL; Light Fluence Up to 45 J/cm²; RF Energy Up to 25 J/cm³; Treated Area 25×12 mm; Pulse Rep Rate 1 Hz; Cooling 5 degrees C; Vascular & Pigmented Lesion Treatment
AC Applicator: Spectrum 400-980 nm IPL; Light Fluence m Up to 18 J/cm²; RF Energy ² Up to 25 J/cm³; Treated Area 25×12 mm; Pulse Rep Rate 1 Hz; Cooling 5 degrees C; Acne Treatment
LV Applicator: Spectrum 915 nm Diode; Light Fluence Up to 140 J/cm²; RF Energy Up to 100 J/cm³; Treated Area 8×5 mm; Pulse Rep Rate 1 Hz; Cooling 5 degrees C; Vascular Lesion Treatment
LVA Applicator: Spectrum 915 nm Diode; Light Fluence 100 – 350 J/cm²; RF Energy Up to 100 J/cm³; Treated Area 8×2 mm; Pulse Rep Rate 1 Hz; Cooling 5 degrees C; Vascular Lesion Treatment
Motif LHR – LHR Mode: Spectrum 810 nm Diode; Light Fluence Up to 50 J/cm²; RF Energy Up to 50 J/cm³; Treated Area 15 x 12 mm; Pulse Rep Rate 3 Hz; Cooling 5 degrees C; “Pain Free” Hair Removal
Motif HR – HR Mode: Spectrum 680 – 980 nm IPL; Light Fluence Up to 45 J/cm²; RF Energy Up to 25 J/cm³; Treated Area 25 x 12 mm; Pulse Rep Rate 1 Hz; Cooling 5 degrees C; “Pain Free” Hair Removal
- Motif Mode – Motif LHR: Frequency 10 Hz; Total Energy Per Pulse 14 J; Total Energy Per Second 140 J;
“Pain Free” Hair Removal
- Motif Mode – Motif HR: Frequency 3 Hz; Total Energy Per Pulse 16 J; Total Energy Per Second 48 J;
“Pain Free” Hair Removal
Motif IR – IR Mode: Spectrum 915 nm Diode; Light Fluence Up to 70 J/cm²; RF Energy Up to 100 J/cm³; Treated Area 8 x 5 mm; Pulse Rep Rate 1 Hz; Cooling 5 degrees C; Focused Wrinkle Treatment
- Motif Mode – Motif IR: Frequency 10 Hz; Total Energy Per Pulse 2.5 J; Total Energy Per Second 25 J; Focused Wrinkle Treatment
Platform Weight:40 kg/88 lbs
Platform Size:54 W x 52.5 D x 140 H cm/21.5 W x 22 D x 55.2 H in.
Electrical Specifications:100-240 VAC
elos Plus
Complete Aesthetic Work Station
- the ultimate multi application platform, provides a full range of the most in demand applications
- uses elōs technology (a combination of optical energy with bi-polar radio frequency) to enable safe and effective treatments on all skin types
- upgradeable, with 10 different applicators for a wide and growing range of clinical indications. The platform expands as your aesthetic practice expands
- includes an intuitive user interface with easy to use guided treatment modes for all of the 10 treatment applicators
- allows for 3 applicators to be connected at the same time
Multi-Application Platform
HANDPIECE/APPLICATOR INDICATED USES:
Sublative RF Applicator – Ablation & Skin Resurfacing, Skin Rejuvenation for an Increase in Collagen
Motif LHR and Motif HR Applicators – “Pain Free” Hair Removal
SR / SRA Applicators – Vascular & Pigmented Lesion Treatment
Sublime Applicator – Facial Contouring and Wrinkle Treatment
Motif IR Applicator – Focused Wrinkle Treatment
AC Applicator – Acne Treatment
LV / LVA Applicators – Vascular Lesion Treatment
DSL Applicator – Diode Hair Removal
The elos® Technology Advantage
The elos Plus features proprietary elos combined-energy technology of optical energies (laser or light) and bi-polar radio frequency (RF).
Less optical energy, when synergistically combined with bipolar RF, improves safety for all skin types
Dual heating via optical and RF energies raises target temperature while maintaining epidermal protection
Engineered for Safety – Easy to Use & Maintain
Proprietary Active Dermal Monitoring feature monitors skin impedance changes during each pulse for added safety
Integrated sapphire contact cooling ensures epidermal protection and increased patient comfort
Intelligent Feedback System (IFS) ensures precise delivery of RF energy regardless of variations in skin impedance
Sublative Applicator Consumables:
64 pin Tip
- Fast full face Sublative Rejuvenation for improved skin tone and texture
- Multiple lifetime configurations for treatment flexibility
44 pin Tip
- Optimized electrode geometry for smaller areas and focused treatment on peri-orbital and peri-oral wrinkles
- Focused treatment of skin irregularities, under-eye laxity and forehead wrinkles