2009 Alma Pixel Co2 Laser for Skin Resurfacing;

Manufactured 09/2009; Excellent Operating and Cosmetic Condition; This Device Has Received Full Maintenance and Certification That this is Fully Functional at Highest Levels; Reason for Selling: Downsizing;

Includes: 7X7 Handpiece Tip, 90 Day Warranty and Free Shipping (zh/pz14)

This Equipment is Fully Functional, Ready for Use, and Ready to Ship.

Financing Available.

Original price was: $95,000.00.Current price is: $14,975.00.

Out of stock

 

Pixel CO2 Consumables

Does the Pixel CO2 Require Consumables to Operate?

Yes, when using the the Femmelift.

What Type of Consumables?

Disposable Vaginal Probes and can be Purchased Through the Manufacturer.

Pixel Co2 Product Specifications
Laser Type / Wavelength RF-excited CO₂, 10,600 nm
Output Power Up to 70 W
Modes CW, Pulse, Repeat, Super Pulse
Fractional Delivery 7×7, 9×9 pixel, iPixel roller, LiteScan scanner
Surgical Applicators 50 mm, 100 mm specific tips; SkinTight non-ablative tip
Special Capability iTED + IMPACT for enhanced topical delivery
Interface & Arm Touchscreen presets; 7-joint articulated arm
Electrical Requirements 120 VAC/16A or 230 VAC/8A
Size & Weight 52″ × 17″ × 21″; ~135 lb
Pixel Co2 Manufacturer Notes

Modes of Operation

The CO2 laser system offers 4 modes of energy delivery:

1. CW Mode (Continuous Wave):

Emits one continuous and consistent laser energy, typically used for excision or cutting.

2. Pulse Mode (Single pulse):

Produces a single pulse of laser energy for more supervised and accurate energy delivery.

On  time Exposure: 10  100 ms

3. Repeat Mode:

Produces a series of either short or long pulses of laser energy at variable speeds.

On-time exposure :10  100 ms

Off  time delay: 10  100 ms

4. Super Pulse Mode:

Super pulse mode provides the highest peak power with the shortest pulse duration, enabling the deepest penetration with minimal residual thermal damage. This mode is designed for performing ablation without inflammation and achieves highly effective results with minimal downtime and enhanced patient comfort.

Benefits of Pixel CO2 laser by Alma:

  • Multiple dermatological and cosmetic surgery indications
  • Versatile applicators for targeted procedures
  • Adjustable treatment patterns
  • Exclusive non-ablative mode
  • Unique Pixel technology
  • Safe for delicate areas
  • Precise&Fast treatment
  • Versatile for high ROI

Indicated Uses:

  • Stretch Mark Removal
  • Skin Resurfacing
  • Scar and Acne Scars Correction
  • Fine Lines & Wrinkle Correction
  • Skin Whitening
  • Melasma Removal

Alma Pixel CO2 is a highly flexible system for char-free tissue ablation, vaporization, excision, incision and coagulation of soft tissue. It allows physicians full control of treatment parameters, including level and depth of ablation and thermal control via pulse duration and mode of energy delivery. This versatility maximizes precision and treatment results while minimizing unnecessary tissue damage.

 

1. Versatile Multi-Application Platform

  • The Pixel CO₂ delivers ablative fractional treatments, featuring advanced options like a powerful scanner or pixel technology, as well as focus applicators for precise surgical use (e.g., cutting, vaporization, coagulation)

  • It automatically optimizes beam parameters for specific indications while also allowing manual adjustment via a user-friendly graphical display.

2. Advanced Fractional & Roller Technology

  • The unique iPixel roller enables rapid treatment of large areas. Its movement triggers high-energy laser pulses that form a row of seven evenly spaced micro-ablative channels for effective tissue remodeling and faster healing.

3. Precision & Technology Built In

  • Utilizes an RF-excited CO₂ laser at 10,600 nm—ideal for skin rejuvenation and surgical applications.

  • Employs Diffractive Optical Elements (DOE) in pixel applicators to create fine pixelated patterns (7×7 or 9×9), enabling both ablative and thermal treatments.

  • High-output options up to 70 W, with preset levels of Low (10 W), Medium (30 W), and High (70 W) to match treatment needs.

4. User-Friendly Interface & Presets

  • The color touchscreen provides intuitive presets based on clinical research for treatments including skin resurfacing, acne scars, fine lines, and wrinkles. Parameters can be manually adjusted as required.

  • The system’s seven-joint articulated arm ensures precise and ergonomic coverage across treatment areas.

5. Multiple Applicator Options

  • Includes a wide range of applicators for different treatments and outcomes:

    • Fractional pixel tips (7×7, 9×9)

    • iPixel roller

    • LiteScan scanner

    • Surgical focusing handpieces (e.g., 50 mm, 100 mm)

    • SkinTight non-ablative tip

    • Femilift probes for gynecological treatments

6. Power Configurations & Protocol Flexibility

  • Available in 30 W or 70 W configurations, adaptable for both dermatology and gynecology via tailored protocols.


Feature Description
Multi-application platform Fractional, scanner, surgical & gynecology applicators
Intelligent presets Auto-optimized parameters via touchscreen, with manual control
iPixel roller Fast treatment for larger areas, improved healing
Laser specifications RF-excited CO₂, 10,600 nm, up to 70 W output
Fractional delivery DOE-based pixelated beams in 7×7 or 9×9 patterns
Ergonomic design 7-joint articulated arm for better coverage, comfort
Power configurations Available in 30 W & 70 W variants
Applicator versatility Wide selection including SkinTight and Femilift

Handpieces NOTES: 

50 mm & 100 mm 

These are stand-alone surgical-style focusing lenses.
You hold them directly over the treatment area, and the CO₂ beam passes straight through their optics.
They can be used:
  • By themselves for cutting, ablation, or coagulation
  • With a scanner (like LiteScan) for fractional resurfacing
  • They are not part of the Pixel 7×7 or 9×9 stamping setup.
On the Alma Pixel CO₂, the 50 mm handpiece is the optical attachment that determines:
  1. Spot size & coverage area – The “50 mm” refers to its focal length. That changes how the beam converges and how large the treated area is at a given working distance.
  2. Beam focus & energy density – A shorter focal length like 50 mm produces a smaller, tighter spot size at closer range, which increases the energy density (more intense treatment per square mm).
  3. Treatment depth & precision – Because it’s more focused, the 50 mm handpiece is typically used for more precise resurfacing, fractional ablation, or targeted lesion removal in smaller zones.
  4. Distance from skin – The lens’ focal distance controls how far the handpiece must be from the skin for optimal energy delivery. A 50 mm lens requires you to work closer to the skin than a 100 mm lens.
In practice, the 50 mm handpiece is often used for:
  • Localized wrinkle and scar revision
  • Fractional skin resurfacing in tighter areas (around eyes, lips, or small scars)
  • Benign lesion removal with higher precision
  • Pixel mode treatments when higher ablation density is needed in a confined zone

In practice, the 100 mm handpiece is often used for:

  • Cutting, vaporization, or excision of soft tissue with high accuracy
  • Common in dermatology, ENT, gynecology, and aesthetic surgery

The 100 mm handpiece focuses the C)2 laser bean into a small, high-intensity spot at a lot longer distance, ideal for precise ablation, cutting, and surgical procedures. It does not pixelate or fractionate the beam – it delivers a solid, continuous beam used in surgical mode, not frational mode.

Feature / Spec 50 mm Handpiece 100 mm Handpiece
Type Focusing (Surgical) Focusing (Surgical)
Focal Length 50 mm 100 mm
Spot Size (typical) ~200–400 µm (smaller focus) ~100–200 µm (smaller, finer beam)
Working Distance Shorter (closer to tissue) Longer (allows more space between hand & tissue)
Precision High (good for controlled ablation) Very high (ideal for delicate work)
Visibility of Field Moderate (closer range reduces visual access) Improved (longer distance gives clearer view)
Common Uses General surgical ablation, dermatology lesions ENT, gynecology, microsurgery, fine dermatology
Beam Divergence More divergence at close range Tighter, more collimated beam
Tissue Penetration Shallow to moderate Moderate to deeper (more precision)
Control & Ergonomics More hand stability required Easier handling with stand-off distance

7×7 / 9×9 Pixel Handpieces
  • These are dedicated fractional optics that contain a Diffractive Optical Element (DOE).
  • The DOE splits the beam into a fixed array of 49 (7×7) or 81 (9×9) microbeams.
  • The Pixel handpiece is its own optical module — the 50 mm and 100 mm lenses do not attach to it.
  • If you want a different focal length with Pixel stamping, you’d swap to a different Pixel handpiece model (not add a 50 mm lens).
FemmeLift Vaginal Probe

The FemiLift is a specialized vaginal CO₂ laser system designed to improve the health and function of the vaginal tissue. It works by delivering fractional CO₂ laser energy inside the vaginal canal, which stimulates the body’s natural healing process. This energy promotes the production of collagen and elastin, two critical proteins responsible for tissue strength, elasticity, and moisture retention. As a result, the vaginal walls become thicker, more elastic, and better lubricated, which helps alleviate symptoms such as vaginal dryness and discomfort.

One of the key benefits of FemiLift is its ability to address vaginal laxity by tightening the vaginal walls. This can improve both physical support and sexual function, enhancing comfort and sensation during intercourse. Additionally, FemiLift may help reduce mild stress urinary incontinence by strengthening the tissues that support the bladder and urethra. It is also effective in treating atrophic vaginitis, a condition characterized by thinning and irritation of the vaginal lining, especially common in post-menopausal women.

The procedure is minimally invasive and typically takes about 15 to 30 minutes. It is usually performed over a series of three sessions spaced several weeks apart to achieve optimal results. Since FemiLift is a non-hormonal treatment, it is a suitable option for women who cannot or prefer not to use hormonal therapies. However, it is important that the treatment is administered by trained healthcare professionals to ensure safety and effectiveness. While FemiLift is not a replacement for surgical interventions, it offers a less invasive alternative for women seeking relief from mild to moderate vaginal health concerns.

* Shipping is included in the Continental USA only. Any shipment outside the lower 48 United States will be shipped at an extra cost. If you live outside this area, please contact us for a free shipping estimate.