2014 Ellman Medley with Erbium Yag 2940nm Handpiece, Q-Switched Nd Yag 532 & 1064nm Handpiece, Diode 810nm Hair Removal Handpiece, IPL Handpiece with Vein Removal, Hair Removal, Skin Rejuvenation and AR Filters; Manufactured 11/17/2014; Excellent Cosmetic and Operating Condition, Single Owner; Received Full Maintenance Service and Certified by Cynosure Technician on 10/30/2017, Record Available Upon Request; Software Version 14.1.09; Handpieces & Pulse Counts: Erbium Yag Handpiece = 12,449 Pulses, Q-Switched Handpiece = 10,409 Pulses, Diode Handpiece = 128,712 Pulses, IPL Handpiece = 1,133 Pulses; Includes: Erbium Yag Adjustable Spot Size Attachment, 532 Spot Size Attachment, Nd Yag Adjustable Spot Size Attachment; Includes Filters for IPL = VR, HR, SR, & AR; Also Includes: Footswitch, & (2) Keys, Operators Manual, Parameter Settings, and 90 Day Warranty.km

$14,995.00

Out of stock

Medley Sparkling Specifications

Erbium Yag Handpiece
Application:Laser skin resurfacing, skin ablation and coagulation, wrinkle and scar reduction
Energy:Up to 1000 mJ
Max Power:2.4 W
Pulse Width:300 us
Wavelength:2940 nm
Beam Divergence:Collimated
Spot Size:1.5 to 6 mm (with zoom lens)
NOHD:>180 m
Repetition Rate:up to 8 pulses per second
Controls:Touch screen LCD, Footswitch
Cooling:Self-Contained Closed Loop

Q-Switched Nd Yag Handpiece
Application:Nd Yag handpiece has two wavelengths of 1064 nm and 532 nm which are used for the treatment of vascular lesions including facial veins, telangiectasias, angiomas, hemangiomas, and pigmented lesions
Energy:Up to 1000 mJ
Maximu Fluence:12 J/cm2
Wavelength:1064 nm and 532 nm
Spot Size:1.5 to 4 mm (with zoom lens)
Pulse Width:10 to 15 ns
Repetition Rate:1 to 6 Hz
NOHD:>1000 m
Aiming Beam:Diode (635 nm, 10 mW Max.)
Beam Delivery:Direct
Controls:Touch screen LCD, Footswitch
Cooling:Self-Contained Closed Loop

810 nm Diode Laser Handpiece
Application:Laser Hair Removal
Wavelength:810 nm
Spot Size:10 x 14 mm
Repetition Rate:1-10 Hz
Fluence:1 to 100 J/cm2
NOHD:>30.1 m
Pulse Width:Auto, 30 ms, 100 ms, 200 ms, 400 ms
Accuracy: +- 10%
Cooling Temperature:0 to 5 C

IPL Handpiece
Application:Four wavelengths – 650 nm, 540 nm, 510 nm, and 450 nm for hair removal, pigment reduction, melanin, photo damaged skin lesions, seborrheic keratosis, and atrophic acne scars
Maximum Fluence:35 J/cm2
Wavelength:450 to 1200 nm
Spot Size:35 x 15 mm
Repetition Rate: 1 Pulse every 3 seconds
Cooling:Self-Contained Closed Loop

Indicated Uses:
– Tattoo Removal
– Pigmented Lesions on Skin Types -IV
– Active Acne
– Uneven Pigmentation
– Vascular Lesions
– Hair Removal
– Superficial Skin Resurfacing
– Fine Lines and Wrinkles
– Micro-Laser Peels
– Sun Damaged Skin

Date Sold