2017 Lumenis Lightsheer Desire with HS & XC Handpieces - 22x35mm & 12x12mm Spot Sizes, 805nm & 1060nm - Hair Removal, Pigment, Vein, Wrinkles (km/boc)s - Rock Bottom Lasers

Shop by Category

Sale!

2017 Lumenis Lightsheer Desire with HS & XC Handpieces – 22x35mm & 12x12mm Spot Sizes, 805nm & 1060nm – Hair Removal, Pigment, Vein, Wrinkles (km/boc)s

Product Question
Email Product

2017 Lumenis Lightsheer Desire with HS & XC Handpieces – 805nm & 1060 nm – Hair Removal, Pigment, Vein, Wrinkles – FOR ALL SKIN TYPES; Manufacture Date: 12/31/2017; Perfect Operating & Excellent Cosmetic Condition, Received Full Maintenance and Certification that this Device is Fully Functional at Highest Levels on 02/19/2022, Service Record Available Upon Request; Reason for Selling: Downsizing; Software Version: GUI 4.31 Desire Build 5, Controller: 4.31 Build 2, FPGA: 516; Included Handpieces with Pulse Counts & Headrooms:  HS = 19,630 Pulses, Headroom = 1.83 (Auto), XC = 126,528 Pulses, Headroom = 1.50; Handpiece Production Date: HS = 02/04/2020, XC = 06/23/2020; Also Includes: (1) HS Handpiece Tip, (1) Patient Eyewear, (1) Operator Eyewear, (1) Key, Operators Manual, Warning Sign, Interlock, Patient Brochures, Pop Up Banner, & 90 Day Warranty.(km/boc24)S

Original price was: $95,000.00.Current price is: $31,975.00.

Out of stock

 

Lightsheer Desire CONSUMABLES

HS Handpiece requires one-time use tips.

These tips can be purchased on eBay for @ $15 each.

Lightsheer Desire PRODUCT SPECIFICATIONS

High Speed (HS) Handpiece

Laser Type: Diode

Wavelength: 805 nm & 1060 nm

Spot Size: 22 x 23 mm

Repetition Rate: Up to 3 Hz

Pulse Repetition: 1-3 Pulses

Fluence: 4.5-12 J/cm2; 1060 nm: 4.5-14 J/cm2

Pulse Width: 30-400 ms

Peak Power: 2310 W

XC Handpiece

Laser Type: Diode

Wavelength: 805 nm & 1060 nm

Spot Size: 12 x 12 mm

Repetition Rate: Up to 3 Hz

Pulse Repetition: 1 Pulse

Fluence: 10-40 J/cm2

Pulse Width: 5-400 ms

Peak Power: 2200 W

ET Handpiece

Laser Type: Diode

Wavelength: 805 nm & 1060 nm

Spot Size: 9 x 9 mm

Repetition Rate: Up to 3 Hz

Pulse Repetition: 1 Pulse

Fluence: 10-100 J/cm2

Pulse Width: 5-400 ms

Peak Power: 1620 W

Lightsheer Desire MANUFACTURER NOTES

The starting point to your success

More and more people desire to have permanent hair reduction. They want a treatment that is effective, fast and comfortable.

To meet these needs, Lumenis, a leader in laser and energy based technologies, developed the LightSheer DESIRE, the new generation of Laser Hair Reduction system from the LightSheer Family of products, so you can grow your business by offering your patients what they DESIRE.

Indications For Use

  • Treatment of vascular lesions, including angiomas, hemangiomas, telangiectasia, and other benign vascular lesions and leg veins.
  • Hair removal, permanent hair reduction*, and the treatment for Pseudofolliculitis Barbae (PFB).
  • Treatment of benign pigmented lesions.
  • Treatment of wrinkles (for 1060nm handpieces only).
  • Use on all skin types (Fitzpatrick skin type I-VI), including tanned skin.

* Permanent hair reduction is defined as the long-term, stable reduction in the number of hairs re-growing when measured at 6, 9 and 12 months after the completion of a treatment regime.

The technology behind the DESIRE

Great clinical results begin with the LightSheer DESIRE 805 nm diode laser empowered by two advanced technologies:

Vacuum Assisted High-Speed Integrated Technology

A large 22×35 mm spot size enables the use of low-fluence and with a unique mechanism for pain reduction provides effective, fast and comfortable treatment.

ChillTip Technology

Integrated contact cooling provides epidermal protection for treatment areas requiring precision and higher fluence.

How Vacuum Assisted Technology Works

  • Vacuum gently draws skin into the handpiece, skin is stretched thin and target is pulled closer to the energy source.
  • Energy is applied to target in which melanocytes are spread apart and blood flow is constricted.
  • Target is damaged and skin is released.

Advantages of High-Speed Vacuum Assisted Technology

  • Efficacy: reduction in competing chromophores enables delivery of laser energy more efficiently.
  • Safety: less energy is absorbed by the epidermis and lower fluence is required since the target is closer to the energy source.
  • Decreased pain: The unique vacuum mechanism activates tactile and pressure skin receptors to inhibit the transmission of pain sensation.

How ChillTip Works

  • Skin is cooled before and during treatment.
  • Skin is compressed. Laser beam applied to skin and target is damaged

Advantages of ChillTip Technology

  • Safety: superior epidermal protection is achieved through ChillTip contact cooling
  • Patient comfort: by continuously cooling the skin, pain and discomfort are significantly reduced.
  • Efficacy: Compression of the skin rotates follicle closer to the surface, blenches blood vessels and reduces competing chromophores. High fluence enables treatment of areas requiring precision and thin, light hair.
* Shipping is included in the Continental USA only. Any shipment outside the lower 48 United States will be shipped at an extra cost. If you live outside this area, please contact us for a free shipping estimate.

Join Our Mailing List

Subscribe to our email list to receive updates on our latest equipment listings.