Excel V+ CONSUMABLES
Are Consumables Required for the Cutera Excel V+? No
Excel V+ PRODUCT SPECIFICATIONS
-
Dimensions: ~40 cm W × 97 cm H × 79 cm D (about 16″ × 35″ × 24″)
-
Weight: ~86 kg (185 lb)
-
Power requirements: 110–120 VAC, 20 A
-
Dual-wavelength system:
• 532 nm KTP (LBO‑enhanced solid-state) – ~50% more powerful than Excel V
• 1064 nm Nd:YAG for deeper targets -
Spot size flexibility:
• Adjustable from 2 mm up to 16 mm (in some sources 14 mm) in 0.5–1 mm increments -
Pulse duration range:
• 0.3 ms – 300 ms total system; CoolView (KTP) 1.5–40 ms; YAG 5–300 ms -
**Fluence (energy density)**:
• KTP: roughly 1.8–42 J/cm²
• Nd:YAG: up to 300 J/cm² -
Repetition rate:
• KTP: 2–12 Hz
• Nd:YAG: up to 10 Hz (CoolView) or 0–2 Hz in some configs *
Excel V+ MANUFACTURER NOTES
The Excel V+ is FDA-cleared and intended for treatment of a wide array of benign conditions using both wavelengths:
-
Vascular lesions: telangiectasia, facial/leg veins, angiomas, port-wine stains, venous lakes, rosacea, diffuse redness, poikiloderma, hemangiomas
-
Pigmented lesions: lentigines, nevi, ephelides, dyschromia, seborrheic keratoses
-
Cutaneous lesions: warts, skin tags, bruising, acne scars, wrinkles, striae, pseudofolliculitis barbae, mild-to-moderate acne
-
Hair removal: small-area hair reduction
excel V+ in action
Two clinically proven wavelengths treat large spot sizes up to 16 mm. Applications include rosacea, diffuse redness, facial veins, leg veins, periorbital veins, angiomas, port wine stains, poikiloderma, wrinkles, venous malformations, bruising, inflammatory acne, benign pigmented lesions, age spots, small-area hair removal, scars, and acne scars.1,2
excel V+ technology
Four compatible handpieces give you even more versatility with excel V+. Deliver the micro-pulsed 532 nm wavelength with our Genesis V™ handpiece, customize spot size and wavelength using the fully-integrated CoolView™, or use the pencil-like Dermastat handpieces to precisely treat small vascular and pigmented lesions.
🔹 CoolView™ Handpiece
Wavelengths: 532 nm & 1064 nm (switchable)
Spot Sizes: 2–16 mm (adjustable in small increments)
Cooling: Contact cooling with sapphire window (5–20 °C)Primary Functions:
-
Treats both superficial (532 nm) and deeper vascular lesions (1064 nm)
-
Ideal for telangiectasias, rosacea, angiomas, leg veins, and venous lakes
-
Also used for pigmented lesions (lentigines, sunspots) and small-area hair removal
-
Large spot sizes allow fast treatment of extensive areas
Best For:
-
Redness/diffuse rosacea
-
Large vessels (legs, face)
-
Pigment removal
-
Bruising (post-injectable)
🔹 Genesis V™ Handpiece
Wavelength: 1064 nm (Nd:YAG, micro-pulsed)
Mode: Non-ablative, low-fluence, micro-pulsed deliveryPrimary Functions:
-
Collagen stimulation and dermal remodeling
-
Improves fine lines, scarring, pore size, and skin texture
-
Treats diffuse redness and rosacea at the dermal level
-
Popular for acne scarring, sebaceous hyperplasia, and early aging signs
Best For:
-
Skin rejuvenation (non-ablative)
-
Redness not caused by visible vessels
-
Fine lines and texture concerns
🔹 Green Genesis™ Mode (within CoolView or dedicated interface)
Wavelength: 532 nm (KTP), micro-pulsed mode
Mode: Non-invasive, low-fluence
Delivery: Either via CoolView handpiece or preset within softwarePrimary Functions:
-
Treats epidermal vascular conditions, especially background redness and flushing
-
Ideal for patients who can’t tolerate full vascular spot treatments
-
Gentle approach for sensitive skin or darker phototypes
Best For:
-
Flushing/blushing
-
Light erythema
-
Diffuse rosacea in sensitive zones (e.g., cheeks, nose)
🔹 Dermastat™ Handpiece
Wavelengths: 532 nm & 1064 nm (selectable)
Spot Sizes: 1–2 mm fixed tips
Design: Pencil-like precision toolPrimary Functions:
-
Targeting very small lesions, such as:
-
Spider angiomas
-
Cherry angiomas
-
Telangiectasias on nose or eyelids
-
Seborrheic keratoses
-
Skin tags
-
-
Allows pinpoint accuracy in hard-to-reach or delicate areas
Best For:
-
Facial detail work
-
Nose veins
-
Tiny vascular or pigmented targets
-
Patients sensitive to larger spot sizes
-