2021 Lumenis Lightsheer Quattro with 2 Handpieces for Diode Hair Removal, Pigment, Vascular, Wrinkles, - (1) XC 805 chill-tip 12 x 12 mm Handpiece, (1) HS 805 High Speed 22 x 35 mm Handpiece - Low Pulses - Free Shipping & Warranty (hm/bc) - Rock Bottom Lasers

Shop by Category

Sale!

2021 Lumenis Lightsheer Quattro with 2 Handpieces for Diode Hair Removal, Pigment, Vascular, Wrinkles, – (1) XC 805 chill-tip 12 x 12 mm Handpiece, (1) HS 805 High Speed 22 x 35 mm Handpiece – Low Pulses – Free Shipping & Warranty (hm/bc)

Product Question
Email Product

2021 Lumenis Lightsheer Quattro with 2 Handpieces for Diode Hair Removal For All Skin Types, Pigment, Vascular, Wrinkles, – (1) XC 805 chill-tip 12 x 12 mm Handpiece, (1) HS 805 High Speed 22 x 35 mm Handpiece;

Manufactured 05/2021;  Excellent Cosmetic and Operating Condition; Extremely Low Pulses; Reason For Selling, Downsizing;

Handpieces Included:

XC 805 Chill-Tip 12 x 12 mm Handpiece = 771,947 Pulses – Provides a Solution for Both Large and Small Areas Requiring Higher Fluence Levels;

HS 805 High Speed 22 x 35 mm Handpiece = 584,572 Pulses; This Handpiece Offers a Unique Pain Reduction Mechanism and Works Without Gel Ideal for Treating Larger Body Area Quickly/Comfortably;

Also Includes: Operator Manual, Key, 90 Day Warranty, and Free Shipping in the Continental USA.(hm/bc25)

Shipping to Canada $250 Extra;

This Equipment is Fully Functional, With No Error Messages, Ready for Use, and Ready to Ship. Actual Photos of the Device are Displayed.

Warranty Includes Cost of Parts, Labor, & Shipping or Travel.

Financing Available.  Training is Available at an Additional Cost.

Original price was: $105,000.00.Current price is: $33,975.00.

Availability: 1 in stock

Lightsheer Quattro PRODUCT SPECIFICATIONS

HS 22 X 35 mm Handpiece

Laser Type: AIGaAs Diode Arrays

Wavelength: 805 nm & 1060 nm

Repetition Rate: Up to 3 Hz

Pulse Repetition: 1-3 pulses

Fluence: 805 nm: 4.5-12 J/cm2; 1060 nm: 4.5-14 J/cm2

Pulse Width: 30-400

Peak Power: 2310 W

Preset Parameters: Yes

Comfort Management: Vacuum-assisted (up to18 inHg)

XC 12 X 12 mm Handpiece

Laser Type: AIGaAs Diode Arrays

Wavelength: 805 nm

Repetition Rate: Up to 3 Hz

Pulse Repetition: 1 pulse

Fluence: 10-40 J/cm2

Pulse Width: 5-400 ms

Peak Power: 2200 W

Preset Parameters: Yes

Comfort Management: Chilltip contact cooling (2˚C)

ET 9 X 9 mm Handpiece

Laser Type: AIGaAs Diode Arrays

Wavelength: 805 nm

Repetition Rate: Up to 3 Hz

Pulse Repetition: 1 pulse

Fluence: 10-100 J/cm2

Pulse Width: 5-400 ms

Peak Power: 1620 W

Preset Parameters: Yes

Comfort Management: Chilltip contact cooling (2˚C)

Platform Specifications

Electrical 100-240 VAC +/-10%, 10 A | 50/60 Hz. | Single-phase grounded outlet

Weight The console weight is: 36 kg (79.4 lbs.)

Dimensions (WxDxH) 51 x 60 x 42 cm; (20.1 x 23.6 x 16.55 in)

Lightsheer Quattro MANUFACTURER NOTES

Laser Hair Removal Device for All Skin Types

LightSheer® QUATTRO™ is a diode laser workstation that is a perfect fit for any practice. Powered by two advanced technologies and featuring 805nm and 1060nm wavelengths, LightSheer QUATTRO can treat all hair types and skin tones.

  • Treat Any Skin Type – including dark and tanned skin, with the 805nm and 1060nm wavelengths.
  • Upgradeable and scalable – enabling you to expand your practice offering.
  • Portable with a compact footprint – to fit every practice.
  • Treatment versatility – Hair removal, wrinkle reduction, benign pigmented & vascular lesions

Lightsheer Quattro Indications for use:

  • Treatment of benign vascular lesions, including angiomas, hemangiomas, telangiectasia, and other benign vascular lesions and leg veins.
  • Hair removal, permanent hair reduction*, and the treatment for Pseudofolliculitis Barbae (PFB).
  • Treatment of benign pigmented lesions.
  • Treatment of wrinkles (for 1060nm handpieces only).
  • Use on all skin types (Fitzpatrick skin type I-VI), including tanned skin. *

HS (High Speed) Handpiece – 22 x 35 mm Spot Size

  • Offers a unique pain reduction mechanism and works without gel.
    Ideal for treating larger body areas, quickly and comfortably.
  • Efficacy – drawing skin into the handpiece reduces competing chromophores and pulls the target closer to the laser source which delivers energy efficiently.
  • Safety – Lower fluence is required per pulse.
  • Decreased pain – Unique vacuum mechanism reduces pain during treatment.Treatment time1,2 Rapid coverage rate without gel or anesthesia.

Chill Tip Integrated Contact Cooling Technology – XC & ET

XC Handpiece – 12 x1 2 mm Spot Size

  • Providing a solution for both large and small areas requiring higher fluence levels.
  • Efficacy – Compression of the skin reduces competing chromophores
  • Safety – Epidermal protection through continuous sapphire contact cooling
  • Patient comfort – Continuously cooling significantly increases comfort.

ET HANDPIECE – 9 x 9 mm Spot Size

  • Designed to treat small areas that require maximum precision.
  • Efficacy – Compression of the skin reduces competing chromophores
  • Safety – Epidermal protection through continuous sapphire contact cooling
  • Patient comfort – Continuously cooling significantly increases comfort.

Permanent hair reduction is defined as the long-term, stable reduction in the number of hairs re-growing when measured at 6, 9 and 12 months after the completion of a treatment regime.

* Shipping is included in the Continental USA only. Any shipment outside the lower 48 United States will be shipped at an extra cost. If you live outside this area, please contact us for a free shipping estimate.

Join Our Mailing List

Subscribe to our email list to receive updates on our latest equipment listings.